Search Results for “chimney flashing installation”
of installation, and a recommendation to test the building for radon every two years. ___ The inspector noted a missing “Radon,” “Radon Fan” or “Radon System” label at the disconnect breaker controlling the electrical circuit to the radon fan. This inspection was performed
). There are exceptions that permit the minimum to be 24 inches (610 mm), including a microwave installed according to the manufacturer's installation instructions. Refer to 2024 IRC G2447.5 and IFGC 623.7. Check that the electrical receptacle in the cabinet above is properly positioned and the cord connection
to be bearing on their tails. b. Insulation is missing from part of the attic floor. c. Trusses have been altered by installation of additional web members. d. Roof load is being transmitted to 2x4 ceiling joists through strips of plywood. Show Details / Explanation You must be logged
side of the coil to the other. Cosmetic problem only. d. Buckling during installation by careless installers. Will worsen with time. Cosmetic only. Show Details / Explanation You must be logged in as an InterNACHI member to see this card's explanation, comments and suggested report narratives. About
Get Started Grow Your Business More… Show Menu Join InterNACHI® Jump to flashcard menu Home Inspection Flashcard #66 Currently only showing flashcards in the Roofing category. Clear filters What's Your Call? What would be your main concern with this evaporative cooler installation? a. Pan corrosion
Get Started Grow Your Business More… Show Menu Join InterNACHI® Jump to flashcard menu Home Inspection Flashcard #150 Currently only showing flashcards in the Roofing category. Clear filters What's Your Call? The variation in the color of shingles on this roof is the result of_____. a. Installation
installation. Show Details / Explanation You must be logged in as an InterNACHI member to see this card's explanation, comments and suggested report narratives. About Membership Already a member? Log in for full access. Prev Card Next Card All Flashcards Back to top Flash Card #6 Flash Card #29 Flash Card
cycling of the roof deck. b. Under-driving during installation. c. Moisture cycling of the roof deck. d. Nail expansion and contraction. Show Details / Explanation You must be logged in as an InterNACHI member to see this card's explanation, comments and suggested report narratives. About Membership
exposure to weather. b. Crevice corrosion caused by stacking panels while they were wet (before installation on the roof). c. Galvanic corrosion from coating aluminum-core panels with galvanized steel. Where the galvanic coating wears thin, moisture catalyzes corrosion. d. Surface corrosion from
. Improper installation d. Falling ice Show Details / Explanation You must be logged in as an InterNACHI member to see this card's explanation, comments and suggested report narratives. About Membership Already a member? Log in for full access. Prev Card Next Card All Flashcards Back to top Flash Card #6