Dishwasher not properly secured to counter top.
Observation
![Observation](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7818-768x576.jpg)
Zip cord is used as permanent wiring, no ground.
Observation
![Observation disposal](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7819-768x576.jpg)
Disposal missing anti-strain device, clamp.
Observation
![Observation non p-trap](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7820-768x576.jpg)
Missing P-Trap.
Observation
![Observation](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7821-768x576.jpg)
No second high loop at dishwasher drain.
Observation
![Observation non-GFCI](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7822-768x576.jpg)
Outlet above sink (within 6' of sink) not GFCI protected.
Observation
![Observation](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7823-768x576.jpg)
GFCI above sink is defective, does not reset.
Observation
![Observation outlet above stove](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/09/100_7824-768x576.jpg)
No outlets are allowed to be installed above stove.
Observation
![Observation](https://www.nachi.org/school/wp-content/uploads/sites/2/2018/05/1.-Under_kitchen_cabinet-768x512.jpg)
- Electrical outlet installed above stove.
- Countertop not fastened down.
- No trap.
- Improperly installed air admittance valve.
- Air admittance valves must terminate a minimum of 4” above the trap arm.
- No anti-siphon method used with the dishwasher drain.
- This condition may allow grey water to siphon back into the washer cabinet where it could contaminate the clean contents.
- Improper garbage disposal wiring.